Caulks
Product Information
Chemical Resistance
Application
Coatings
THP-1000
Application
THP-2000
Application
Adhesives
THA-3000
Application
MSDS Sheets
|
|


Fluorodyn Coating THP-1000
Application Instructions
Surface Preparation: Priming is not usually necessary when surfaces are
Thoroughly cleaned. Coat a test area to make certain of good adhesion.
Prepare surfaces according to these guide lines:
Steel: Before sand blasting remove all traces of oil and grease using a suitable Detergent, followed by a clean water washing.
All Steel surface should be sandblasted to white metal in accordance with NACE
Specification # 1.
Dust and sand particulate should be removed by suitable means.
Aluminum: Surface must be roughed up either by sand blasting or mechanically to ensure a sufficient anchor pattern. Remove all oxidation.
Dust and particulate should be removed.
Wipe surface clean with Methyl Ethyl Keytone prior to application.
For additional adhesion surface can be primed with Chemloc 5150.
Flexible Materials: Rubber plastics, fabric, etc., should be cleaned of surface contaminants.
Concrete Surfaces:
New surfaces: should have all construction dust and curing compound removed. Free of all loose contaminates.
Old Surfaces: should be cleaned to remove any surface contaminants. Thermodyn highly recommends hydroblasting or sandblasting prior to application.
Application Temperature: Fluorodyn Coating made with Viton® was designed to be applied at ambient temperature. Thermodyn recommends testing prior to use.
Application Methods: Brushing, Spraying, or Dipping. Apply multiple coats to obtain the desired thickness. Coating should dry to the touch, approximately 60 minutes, before applying another coat.
Curing Material: After last coat has been applied and allowed to dry for 48 hours, Surface vulcanization can be achieved by adding dry indirect heat (250ºF) for approximately 1 hour. If possible, Step Curing is recommended. Increase temperature 50º every 30 minutes once all solvent has evaporated. Note: Rapid increase in temperature will result in blistering of coating.
For additional Vulcanization methods please contact Thermodyn (800) 654-6518.
Coating Storage: Coating should be stored in a cool dry area. For extended storage, material should be stored in refrigerator.
|